Guide

How to connect a Realtime machine to the cloud

Open Menu › Comm. › Cloud Server Setting on the machine and look at the server mode. Realtime T-series machines such as the T304F+ use FkWeb: choose it and enter the server URL http://devices.otomateworld.com/ebkn. Models that offer ADMS instead use the same settings as eSSL: server devices.otomateworld.com, port 80, HTTPS off. Then add the machine’s serial number in OTOMATE.

Updated · By the OTOMATE team

FkWeb or ADMS: which does my machine use?

Realtime sells machines built on more than one platform, so the cloud setting is not the same on every model.

What you seeWhat to doExamples
Server mode offers FkWebChoose FkWeb, URL http://devices.otomateworld.com/ebknT-series, such as the T304F+
ADMS or Web Server with address and portEnable Domain Name on, devices.otomateworld.com, port 80, HTTPS offModels on the ZKTeco platform
Only Realtime’s own cloud app, no server settingCan’t connect to OTOMATE yet. Staff can punch from the OTOMATE app insteadSome app-only models

A Realtime T304F+ is connected to OTOMATE over FkWeb today, and its punches, staff list and stored records come through. Other FkWeb models use the same protocol; tell us your model and we will confirm before you change anything.

Step by step

  1. Connect the machine to the internet

    Open Menu › Comm. and set up the network: DHCP on, or an IP address, gateway and DNS typed in (8.8.8.8 is a safe DNS). Wi-Fi models can use Wi-Fi.

  2. Open Cloud Server Setting and check the mode

    In Menu › Comm., open Cloud Server Setting. Look at what the server mode offers: FkWeb or ADMS. The name of the screen can vary a little by model and firmware.

  3. FkWeb (T-series such as the T304F+): enter the server URL

    Choose FkWeb and enter http://devices.otomateworld.com/ebkn as the server (web server) URL, exactly as written, including http:// and /ebkn.

  4. ADMS models: enter the address and port instead

    If the machine offers ADMS rather than FkWeb, turn on Enable Domain Name, set the server address to devices.otomateworld.com and the port to 80, and leave HTTPS and proxy off.

  5. Check the date and time, then save

    Make sure the machine’s date and time are right, save, and go back to the main screen. Note the serial number from System Info or the sticker.

  6. Add the machine in OTOMATE

    In OTOMATE, open Devices › Add device, choose brand Realtime, enter the serial number and pick the time zone. You don’t choose FkWeb or ADMS in OTOMATE: it recognises the machine by its serial number whichever way it talks.

  7. Punch once to test

    Punch on the machine. It appears in the attendance log within seconds, and the machine shows as online.

What OTOMATE does with an FkWeb machine

  • Punches are sent live, the moment they happen.
  • When the machine connects, and every six hours after that, OTOMATE reads the staff enrolled on it and the punches stored in its memory, so anything punched while the internet was down is filled in. A punch received twice is stored once.
  • OTOMATE keeps the machine’s clock right.
  • When you rename or remove someone in OTOMATE, the change is sent to the machine for people already enrolled on it. These two commands follow Realtime’s FkWeb documentation but are not yet confirmed on a real machine; if a machine refuses one, OTOMATE shows it as failed and changes nothing else. New staff are enrolled on the machine itself, as before.
  • OTOMATE only ever sends read commands, time setting and one-person changes to an FkWeb machine. Commands that would clear users or records are blocked in the server’s code, so the machine’s data can’t be wiped from OTOMATE.

If it doesn’t connect

FkWeb URL incomplete
It must be the full http://devices.otomateworld.com/ebkn. Without /ebkn some firmware still works, but type it in full.
No internet
Check the IP address, gateway and DNS under Menu › Comm. Try DNS 8.8.8.8.
Still shows waiting in OTOMATE
Check the serial number you typed matches the one on System Info, then restart the machine.
Times look wrong
Correct the machine’s date and time, and check the time zone chosen for the machine in OTOMATE.

Questions people ask

Something else? Call +91 90536 35607 or write to hello@otomateworld.com.

Where is the Cloud Server Setting on a Realtime machine?

Under Menu › Comm. on most models. The screen is usually called Cloud Server Setting; on some ADMS models it is called ADMS or Web Server.

What URL do I enter for FkWeb?
http://devices.otomateworld.com/ebkn. It starts with http://, not https.
Does the Realtime T304F+ work with OTOMATE?

Yes. A T304F+ is connected to OTOMATE over FkWeb, with live punches and its staff list and stored records read from the machine.

My Realtime model only works with Realtime’s own app. Can it connect?

Not yet. Models with no Cloud Server, ADMS or FkWeb setting can’t send punches to another server. Your staff can punch from the OTOMATE app with a selfie and location until you change machines.

Are punches made while the internet was down lost?

No. The machine keeps them, and OTOMATE reads its stored records when it reconnects and every six hours, so the gap is filled in with the original times.

Can I add new staff to the machine from OTOMATE?

On FkWeb machines, enrol new staff on the machine as usual; OTOMATE picks them up from the machine. Renames and removals made in OTOMATE are sent to the machine, though this is not yet confirmed on real FkWeb hardware, so check the machine after the first change. On ADMS models, people added in OTOMATE are sent to the machine as well.

Not sure which mode your machine has?

Send us the model, or book a free demo and we’ll connect your Realtime machine with you on a call.